Powered by John Deere 6068CG550
Emissions: Tier 4 Final EPA-Certified for Mobile “NonRoad” Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 250 kVA / 200 kW
Prime Power Rating: 225 kVA / 180 kW
Fuel Capacity 800L / 212Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Cummins QSL9-G3
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 250 kVA / 200 kW
Prime Power Rating: 225 kVA / 180 kW
Generator Set Specifications
Engine Data Sheet
Product Brochure
Powered by Perkins 1706D-E93TAG1
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 313 kVA / 250 kW
Prime Power Rating: 281 kVA / 225 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Powered by John Deere 6090CG550
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 375 kVA / 288 kW
Prime Power Rating: 325 kVA / 260 kW
Fuel Capacity: 920 L
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1506A-E88TAG5
Emissions: Tier 1 Rated, for International Use Only
50 Hz Power Rating at 3 Phase
Standby Power Rating: 335 kVA / 267 kW
Prime Power Rating: 300 kVA / 240 kW
Fuel Capacity 8-10 Hr
Generator Set Specifications v1
Generator Set Specifications v2
Engine Data Sheet v1
Engine Data Sheet v2
Alternator Specifications
Product Brochure
Powered by Cummins QSL9-G7
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 375 kVA / 300 kW
Prime Power Rating: 344 kVA / 275 kW
Generator Set Specifications
Engine Data Sheet
Product Brochure
Powered by Doosan P126TI-II
Emissions: Tier 1 Rated, for International Use Only
60 Hz Power Rating at 3 Phase
Standby Power Rating: 388 kVA / 311 kW
Prime Power Rating: 348 kVA / 278 kW
Fuel Tank Capacity (Enclosed): 385 Liters
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1706D-E93TAG2
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 375 kVA / 300 kW
Prime Power Rating: 338 kVA / 270 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Powered by Scania DC13 084A
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 385 kVA / 300 kW
Prime Power Rating: 350 kVA / 280 kW
Fuel Capacity 790L / 209Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure