For restaurants, a reliable power supply is crucial to maintain operations and keep customers satisfied. Restaurant generators from Americas Generators are designed to ensure that your kitchen, dining area, and essential equipment stay powered even during unexpected outages. Our generators provide the consistent and dependable energy needed to preserve food quality, keep refrigeration units running, and maintain a comfortable environment for guests, ensuring your business stays operational no matter the circumstances.
At Americas Generators, we understand the unique power requirements of the food service industry. Our restaurant generators are tailored to meet these needs, offering solutions that fit various restaurant sizes and power demands. Whether you’re preparing for an upcoming event or simply want peace of mind, our team is here to help you choose the right generator that guarantees seamless operation for your establishment.
Showing 1–12 of 70 results
Powered by Perkins 403D-11G
Emissions: Tier 4 interim EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 12.4 kVA / 10 kW
Prime Power Rating: 11.2 kVA / 9 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Kubota V1505-E4BG1
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 16.5 kVA / 14 kW
Prime Power Rating: 15.5 kVA / 12.5 kW
Fuel Capacity 110L / 29 Gal
Leroy Somer Alternator LSA40S4
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Kubota V1505-E4BG1
Emissions: Tier 4 Final EPA-Certified for Mobile “NonRoad” Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 16.5 kVA / 13.5 kW
Prime Power Rating: 15.5 kVA / 12.5 kW
Fuel Capacity 110L / 29Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 403D-15G
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 20 kVA / 15 kW
Prime Power Rating: 18 kVA / 14 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 404D-22G
Emissions: Tier 4 interim EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 26 kVA / 21 kW
Prime Power Rating: 24 kVA / 19 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 404D-22G
Emissions: Tier 4i EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 25 kVA / 20 kW
Prime Power Rating: 21 kVA / 17 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Powered by Kubota D1803-CR-TIE4BG
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 27.5 kVA / 22 kW
Prime Power Rating: 25 kVA / 20 kW
Fuel Capacity 140L / 37Gal
Leroy Somer Alternator LSA42.3VS2
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Kubota D1803-CR-TIE4BG
Emissions: Tier 4 Final EPA-Certified for Mobile “NonRoad” Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 28 kVA / 23 kW
Prime Power Rating: 25 kVA / 21 kW
Fuel Capacity 140L / 36.9 Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 404D-22TG
Emissions: Tier 4i EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 35 kVA / 28 kW
Prime Power Rating: 31.5 kVA / 25.2 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Powered by Perkins 404D-22TG
Emissions: Tier 4 interim EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 37 kVA / 29 kW
Prime Power Rating: 35 kVA / 27 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Kubota V2403-CR-TIE4BG
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 38 kVA / 30 kW
Prime Power Rating: 35 kVA / 28 kW
Leroy Somer Alternator LSA42.3VS3
Fuel Capacity 210L / 55.5Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 404D-22TAG
Emissions: Tier 4i EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 40 kVA / 32 kW
Prime Power Rating: 36 kVA / 29 kW
Leroy Somer Alternator
Generator Set Specifications v1
Generator Set Specifications v2
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Showing 1–12 of 70 results
Keep your restaurant running smoothly with reliable power solutions from Americas Generators. Every generator we offer is factory tested and certified, ensuring you can serve your customers without interruption, even during power outages.
When you purchase a generator for your restaurant from Americas Generators, you receive:
We supply restaurant generators worldwide, using high-quality parts from trusted names like Cummins, Perkins, and John Deere. Whether you need prime power, standby generators, or emergency generators, Americas Generators has the perfect solution to keep your kitchen operational.
We also offer:
Regular maintenance is crucial for restaurant generators. This video shows you how to perform a load bank test on a diesel generator, ensuring your equipment is always ready when needed.
Choosing the right generator for your restaurant can be daunting. Here are answers to some common questions to help you make an informed decision.
A generator ensures that your restaurant can continue operating during a power outage, keeping essential equipment like refrigerators, ovens, and lighting functional. This prevents food spoilage, maintains customer service, and minimizes revenue loss during unexpected power interruptions.
Yes, installing a generator in a restaurant requires careful planning to ensure it meets all local codes and regulations. Considerations include proper ventilation, noise reduction measures, and selecting a generator that can handle peak power loads during busy service times. Consulting with a professional installer is highly recommended.
Regular maintenance is crucial to keep your generator in top condition. It’s recommended to perform routine checks at least once a month, with more comprehensive servicing every six months. This includes inspecting fuel levels, testing the battery, and running the generator to ensure it’s ready for use at any time.
America’s Generators is your go-to source for all your restaurant’s power generation needs. With our extensive range of products, comprehensive services, and commitment to excellence, we are the ideal partner for ensuring reliable and efficient power solutions. Whether you need a backup generator for your restaurant or a customized power solution for a food service chain, Americas Generators has the expertise and inventory to meet your needs.